Number of beams |
2 - 128 |
Object detection capability |
14mm, 30mm, 40mm, plus perimeter guarding systems |
Detection zone |
141 - 2391mm |
Range |
Perimeter guard 0.5 - 20 metres (model dependent), 14mm guard - 0.5 - 4 metres, 30mm guard - 0.5 - 6 metres, 40mm guard - 3 - 15 metres
|
Light type |
Infrared 880nm |
Response time |
20ms (40ms relay version) |
Operating temperature |
0 °C to +50 °C Heater Off -30 °C to +50 °C Heater On |
Enclosure rating |
IP67 |
Status indicators |
Status & Diagnostic LEDs |
Status indication |
Transmitter (TX)
PWR (Power) - Red LED on = Power connected
STAT (Status) - Green LED on = Alignment ok
MUT (Mute) - Yellow LED on = Muted
MU1 (Mute1) - Blue LED on = Mute 1 on
MU2 (Mute2) - Blue LED on = Mute 2 on
Receiver (RX)
ON - Green LED on = Light curtain safety reset and OSSDs on
OFF - Red LED on = Light curtain safety off
LO1 (Lockout 1) - Yellow LED on = OSSD fault
LO2 (Lockout 2) - Yellow LED on = Mute disparity fault (MU1 & MU2)
EDM (External Device Monitoring) - Yellow LED on = EDM on |
Power supply requirement |
24V DC 2A ±10% |
Current consumption |
1A maximum |
Connection |
M12 - 8 way pin - IP65 |
Classification |
BS EN 61496-1, BS IEC 61496-2 Type 4, BS EN 954-1 Category 4, EN ISO 13849-1 PL e, BS EN 61508 SIL 3 |
Warranty |
1 Year |
External Device Monitoring(EDM) |
+24V DC = on |
Muting |
Dual mute inputs. +24V DC = on |
Mode select standard |
Manual reset Green = reset (+) switch, Yellow + EDM (+) |
Mode select with dip switch |
Auto reset with EDM, floating blanking, fixed blanking, heater, mute time out, mute disparity, parti |
Reset |
+24V DC = on |
Safety outputs |
Electronic 50 mA (OSSD 1 & OSSD 2) |
Mute output |
Electronic 50 mA |